UPS Med Grade Tower Line 1000VA 230V
- Power: 1000 VA at 230V
- Quick switchover to battery operation (uninterruptible power supply)
- Compact tower case – space-saving and flexible integration
- Protection against power failures, voltage fluctuations & data loss
- IEC 60601-1:2005 + A1:2012
UPS Med Grade Tower Line 1000VA 230V
Reliable UPS solution for medical applications
Provides IEC 60601-1 compliant emergency power supply for the medical sector of 1 kVA/750 W, ideal for use in patient care areas. The built-in isolation transformer provides complete isolation while maintaining AC surge protection in all modes.
Tripp Lite's SMX1200XLHG UPS system for the medical sector offers reliable battery backup and complies with IEC 60601-1 regulations for use in hospitals, making it ideal for use near patients. Its 1 kVA/750 W capacity provides up to 27.5 minutes of runtime at half load or 11 minutes at full load, allowing you to continue working during short power outages and perform a proper system shutdown during longer outages.
The integrated line-interactive voltage regulation corrects voltage drops up to 155 V and surges up to 274 V to a normal 230 V nominal output voltage without drawing on battery power. The SMX1200XLHG's built-in isolation transformer with Faraday shielding provides complete isolation and eliminates common-mode interference while maintaining full AC surge suppression in all operating modes. The cumulative leakage current of all connected devices is less than 100 microamperes.
This UPS system has six IEC320 C13 outlets suitable for hospitals and has an IEC320 C14 plug suitable for hospitals on a 15 cm long dongle. All six outlets offer both backup protection and surge protection with a power rating of 340 joules.
The SMX1200XLHG also features diagnostic LEDs, a USB port, and a serial DB9 port, which, when used with the included Tripp Lite PowerAlert software, ensure safe, automatic system shutdown and file saving in the event of a prolonged power outage.
Benefits:
- Specially developed for medical, non-life-sustaining applications
- Power: 1000 VA at 230 V
- Quick switchover to battery operation (uninterruptible power supply)
- Compact tower case – space-saving and flexible integration
- Protection against power failures, voltage fluctuations, and data loss
- Easy installation and operation
- IEC 60601-1:2005 + A1:2012
Specification
| Important data | |
|---|---|
| UPC code | 037332140425 |
| USV type | Line-interaktiv |
| Input phase | Single-phase |
| Nominal input power (maximum load) | 5 A |
| Supported nominal input voltage(s)) | 230 V AC |
| UPS input connection type | C14 input |
| UPS input cable length (m) | 0.2 |
| Recommended electrical supply | 10 A 230 V |
| Voltage compatibility (VAC) | 230 |
| Output capacity (VA) | 1000 |
| Output capacity (kVA) | 1 |
| Output capacity (Watt) | 750 |
| Output capacity (kW) | 0.75 |
| Rated voltage details | 230 V nominal output voltage of the inverter |
| Frequency compatibility | 50 / 60 Hz |
| Infos of the frequency compatibility | Autom. frequency selection |
| Output voltage regulation (mains mode) | -18 %, +8 % |
| AC output waveform (battery mode) | PWM sine wave |
| Supported nominal output voltage(s)) | 220 V; 230 V; 240 V |
| Output sockets | (6) C13 |
| Individually controllable load banks | No |
| Battery kind | Valve-regulated lead-acid battery (VRLA) |
| Runtime at full load (min.) | 11 |
| Runtime at half load (min.) | 27.5 |
| Extendable term | Yes |
| Description of the extendable term | Supports extended runtime with optional BP36V15-2U (limit 1) and BP36V42-3U external battery pack (multi-pack compatible) |
| Compatibility of the external battery | BP36V15-2U (limitation 1); BP36V42-3U (Multipack compatible); BP36V27-2US (Multipack compatible) |
| DC system voltage (VDC) | 36 |
| Battery charging rate (batteries included) | Less than 4.5 hours from 10% to 90% |
| Battery access | The battery access door allows hot-swap battery replacement without turning off connected devices. |
| Internal UPS replacement battery cartridge | RBC36SLT |
| Typical battery life | 3–6 years, depending on usage |
| Description of voltage regulation | The line-interactive UPS offers 2 voltage drop correction stages and one surge adjustment stage to maintain a usable, computer-based output without battery pack power consumption over an input voltage range of 155 to 274 V A |
| Overvoltage correction | Input voltages between 245 and 274 V (AC) are reduced by 9% |
| Undervoltage correction | Input voltages between 183 and 199 are increased by 10% |
| Correction of severe undervoltage | Input voltages between 156 and 182 are increased by 21% |
| Switch | Yes. There are two front-mounted pushbutton switches for system activation, self-test, and alarm bypass functions |
| Acoustic alarm | The audible alarm is muted at the factory to ensure quiet operation. Using our free PowerAlert UPS management software, the audible alarm can be restored to indicate power failure, overload conditions, and low battery pack events |
| LED display | 5 LEDs indicate mains power, battery power, overload, voltage regulation, and battery status (low or replacement required) |
| UPS AC suppression joule rating | 340 |
| EMI/RFI AC noise suppression | Yes |
| Response time AC suppression | Immediately |
| Primary form factor | Tower |
| Cooling method | Cooling via rear cooling fan |
| Installation form factors supported with included accessories | Tower |
| Supports installation of form factors with optional accessories | Wall mount (UPSWM tower mounting kit) |
| Depth of primary UPS (mm) | 231 |
| Primary UPS height (mm) | 323 |
| Width of primary UPS (mm) | 191 |
| Packaging dimensions (HWD / Zoll) | 18.50 x 12.20 x 13.38 |
| Packaging dimensions (HWD / cm) | 46.99 x 30.99 x 33.99 |
| Packaging weight (lbs.) | 48.80 |
| Packaging weight (kg) | 22.14 |
| USV housing material | PVC |
| Dimensions of the UPS power supply module (HBT, cm) | 32.26 x 19.05 x 23.11 |
| Dimensions of the UPS power supply module (HBT / Zoll) | 12.7 x 7.5 x 9.1 |
| Weight of the UPS power supply module (kg) | 20.64 |
| Weight of the UPS power supply module (lbs.) | 45.5 |
| Weight of the unit (lbs.) | 45.5000 |
| Weight of the unit (kg) | 20.64 |
| Operating temperature | +32 to +104 °F / 0 to +40 °C |
| Storage temperature | +5 to +122 °F / -15 to +5 ° C |
| Relative humidity | 0 to 95 %, non-condensing |
| AC mode BTU/h (full load) | 252.2 |
| Heat dissipation in battery mode (BTU/hour) at full load | 252.2 |
| Description of the network management card | Network management is not supported |
| Communication interface | USB; DB9 serial |
| Transfer time | 2-4 milliseconds |
| Low voltage transmission to battery power (setpoint) | 155 |
| High-voltage transmission to battery power (setpoint) | 274 |
| Cold start (starting in battery mode during a power failure) | Cold start operation is supported |
| UPS functions with high availability | Surge protection/radio interference suppression |
| Grounding details | Ground potential equalization connector: POAG-S6/20 |
| UPS applications | Hospital/medical |
| Product certification | UL 60601-1 |
| Product Compliance | RoHS; CE (Europa) |
| Product warranty (international) | 2 years restricted warranty |