Acceptance test according to DIN 6868-157

Testing & calibration

The partial acceptance test according to DIN 6868-157:2014-11 involves testing and calibrating a diagnostic workstation with one or two screens (including monitor, graphics card or graphics driver, display software such as DICOM viewer, and display sources such as PACS).

In accordance with §16 of the German X-ray Ordinance (RöV), an acceptance test in accordance with DIN 6868-157 must be carried out during the installation and configuration of an image reproduction system. Among other things, this test checks whether the integrated screen of the image reproduction system is controlled at the correct resolution and whether the required reference values are complied with in accordance with the declared room class and the diagnostic method. Both the area of activity and the ambient light are taken into account, as they have a significant influence on the image quality of the monitor.


Procedure:

  • Testing and calibration of a device
  • Consistency test
  • Provision of calibrated measuring equipment as required by regulations
  • Calibration according to DICOM §14 standard at the installation site, before each acceptance test
  • Tests according to the current DIN standards, in this case DIN 6868-157
  • Preparation of test reports in paper and file form (PDF file)
  • Explanations of the commission recommendations of the medical association
  • Test recommendations for systems that are not yet subject to a valid test standard
  • Identification of tested monitors (otherwise the responsibility of the radiation protection officer)
  • Arrival/departure throughout Germany


Notes: Minimum requirements for image reproduction devices DIN 6868-157. DIN 6868-157: Room classes

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Similar products

Similar products

Baaske LS01 Medical Wireless Silicone Laser Mouse
Wireless medical-grade silicone mouse with a range of up to 10 m and an ergonomic design for both left- and right-handed users. It can be disinfected quickly and thoroughly.
Baaske LS01 Medical Silicone Laser Mouse
Seamless, fully silicone-coated laser mouse with an IP68 protection rating. Works on virtually any surface and is easy to disinfect.
Baaske LS01 Medical Silicone Laser Mouse
Set consisting of a medical-grade silicone keyboard and a matching hygienic mouse for sensitive areas. Fully sealed surfaces allow for easy disinfection.
Baaske ST Medical Silicone Laser Mouse
Seamless, IP68-rated waterproof silicone laser mouse with 1,500 dpi and a convenient touch-scroll feature for precise control in sensitive work environments. Easy to disinfect.
Man & Machine Hygienic Silicone Mighty Mouse
A fully sealed IP68-rated all-silicone mouse that can be completely submerged in disinfectant and meets the most stringent medical EMC standards.