UPS Med Grade Tower Line 700VA 230V with lithium battery
Reliable UPS solution for medical applications
This 230V SmartPro® hospital-grade UPS is fully compliant with UL 60601-1 regulations when plugged into a hospital-grade outlet, which makes it ideal for use in medical facilities, including patient care vicinities. It allows you to work through short power failures, and gives you enough time to safely save files and shut down your system in case of a prolonged blackout.
Long-Lasting LiFePhos battery (10,000 cycles)
This UPS system for hospitals contains a replaceable lithium iron phosphate (LiFePhos) internal battery that provides up to 30 times the cycle life of traditional sealed lead acid (SLA) batteries. The 6-outlet UPS system provides up to 42 minutes of battery backup at half load and 18 minutes at full load. During normal operation, incoming utility power keeps the replaceable internal battery fully charged, so backup power will always be available..
Automatic voltage regulation (AVR)
AVR protects your equipment from incremental hardware damage, data loss and performance problems caused by brownouts. This UPS for medical equipment can correct brownouts as low as 155V and overvoltages as high as 274V back to nominal 230V power without drawing on the battery backup needed to support your equipment during a blackout.
Built-In isolation transformer offers full isolation
The isolation transformer with Faraday shield offers full isolation and removes common mode noise while maintaining full AC surge suppression in all modes. Cumulative leakage current of all connected equipment is less than 100 microamps.
Combats electromagnetic interference
Various electromagnetic and radio sources found in virtually every home and business can cause disruptive interference on the AC line. Known as EMI (electromagnetic interference) and RFI (radio frequency interference), this line noise is a common cause of performance problems and can lead to incremental hardware damage, data corruption and audio/video transmission problems. This medical-grade UPS system incorporates technology that filters out disruptive line noise so that it won’t affect your equipment.
Easy-to-read LEDs & alarm report
Front-panel LED indicators monitor essential information, such as line power, battery power, overload, voltage regulation and battery low/replace status. An audible alarm will sound in case of low battery, excessive load and power failure.
Saves your files, even when you’re away
USB and DB9 serial ports connect to your computer with the included cables. These ports communicate with free downloadable PowerAlert® software for safe, unattended system shutdown and file saves in the event of a prolonged power failure.
Tower form factor for easy placement on a nurse’s station or mobile medical cart
The long-lasting PVC housing fits easily on a desktop, shelf or anywhere else power is needed. The 15-centimeter (sixinch) dongle with hospital-grade C14 plug connects to a properly grounded AC wall outlet.
Benefits:
- Lithium battery backup allows time to save files and safely shut down during blackouts
- 6 C13 hospital-grade (HG) outlets provide power to medical equipmente
- Approved for use within the patient care vicinityn
- Approved to EN60601-1-2:2015, 4th edition
- Alarm and front-panel LEDs report online, battery, fault and overload conditions
- 10,000-cycle LiFePO4 battery lasts up to 30x longer than comparable SLA batteries
Specification
| Important data | |
|---|---|
| UPC code | 037332224804 |
| USV type | Line-interaktiv |
| Input phase | Single-phase |
| Nominal input power (maximum load) | 3,6 A |
| Supported nominal input voltage(s)) | 230 V AC |
| UPS input connection type | C14 input |
| UPS input cable length (m) | 0.2 |
| Recommended electrical supply | 10 A 230 V |
| Voltage compatibility (VAC) | 230 |
| Output capacity (VA) | 700 |
| Output capacity (kVA) | 0.7 |
| Output capacity (Watt) | 450 |
| Output capacity (kW) | 0.45 |
| Rated voltage details | 230 V nominal output voltage of the inverter |
| Frequency compatibility | 50 / 60 Hz |
| Infos of the frequency compatibility | Autom. frequency selection |
| Output voltage regulation (mains mode) | -18 %, +8 % |
| AC output waveform (battery mode) | PWM sine wave |
| Supported nominal output voltage(s)) | 220 V; 230 V; 240 V |
| Output sockets | (6) C13 |
| Individually controllable load banks | No |
| Battery kind | Lithium-ion (LiFePO4) |
| Runtime at full load (min.) | 14.5 |
| Runtime at half load (min.) | 36 |
| Extendable term | No |
| DC system voltage (VDC) | 36 |
| Battery charging rate (batteries included) | Less than 3,6 hours from 10% to 90% |
| Battery access | The battery access door allows hot-swap battery replacement without turning off connected devices. |
| Internal UPS replacement battery cartridge | RBC53L |
| Typical battery life | 3–6 years, depending on usage |
| Description of voltage regulation | The line-interactive UPS offers 2 voltage drop correction stages and one surge adjustment stage to maintain a usable, computer-based output without battery pack power consumption over an input voltage range of 155 to 274 V A |
| Overvoltage correction | Input voltages between 245 and 274 V (AC) are reduced by 9% |
| Undervoltage correction | Input voltages between 183 and 199 are increased by 10% |
| Correction of severe undervoltage | Input voltages between 156 and 182 are increased by 21% |
| Switch | Yes. There are two front-mounted pushbutton switches for system activation, self-test, and alarm bypass functions |
| Acoustic alarm | The audible alarm is muted at the factory to ensure quiet operation. Using our free PowerAlert UPS management software, the audible alarm can be restored to indicate power failure, overload conditions, and low battery pack events |
| LED display | 5 LEDs indicate mains power, battery power, overload, voltage regulation, and battery status (low or replacement required) |
| UPS AC suppression joule rating | 340 |
| EMI/RFI AC noise suppression | Yes |
| Response time AC suppression | Immediately |
| Primary form factor | Tower |
| Cooling method | Cooling via rear cooling fan |
| Installation form factors supported with included accessories | Tower |
| Supports installation of form factors with optional accessories | Wall mount (UPSWM tower mounting kit) |
| Depth of primary UPS (mm) | 229 |
| Primary UPS height (mm) | 325 |
| Width of primary UPS (mm) | 191 |
| Packaging dimensions (HWD / Zoll) | 18.50 x 12.20 x 13.38 |
| Packaging dimensions (HWD / cm) | 46.99 x 30.99 x 33.99 |
| Packaging weight (lbs.) | 45.40 |
| Packaging weight (kg) | 20.59 |
| USV housing material | PVC |
| Dimensions of the UPS power supply module (HBT, cm) | 32.51 x 19.05 x 22.86 |
| Dimensions of the UPS power supply module (HBT / Zoll) | 12.8 x 7.5 x 9 |
| Weight of the UPS power supply module (kg) | 19.10 |
| Weight of the UPS power supply module (lbs.) | 42.1 |
| Weight of the unit (lbs.) | 42.1000 |
| Weight of the unit (kg) | 19.10 |
| Operating temperature | +32 to +104 °F / 0 to +40 °C |
| Storage temperature | +5 to +122 °F / -15 to +5 ° C |
| Relative humidity | 0 to 95 %, non-condensing |
| AC mode BTU/h (full load) | 208.6 |
| Heat dissipation in battery mode (BTU/hour) at full load | 189.1 |
| Description of the network management card | Network management is not supported |
| Communication interface | USB; DB9 serial |
| Transfer time | 2-4 milliseconds |
| Low voltage transmission to battery power (setpoint) | 155 |
| High-voltage transmission to battery power (setpoint) | 274 |
| Cold start (starting in battery mode during a power failure) | Cold start operation is supported |
| UPS functions with high availability | Surge protection/radio interference suppression |
| Grounding details | Ground potential equalization connector: POAG-S6/20 |
| UPS applications | Hospital/medical |
| Product certification | UL 60601-1 |
| Product Compliance | RoHS; CE (Europa) |
| Product warranty (international) | 2 years restricted warranty |