Network isolators and galvanic isolation of medical electrical equipment

Banner_Netzwerkisolator_network_isolator_

Isolators for medical applications

Galvanic isolation of medical electrical devices.

Network isolators and isolators for the patient environment are used in the medical field to protect the patient from vagabonding currents, also-called leakage and compensating currents. This currents can occur when an active medical device is connected to a non-medical device such as an office PC or laptop. When healthcare facilities combine medical electrical devices, they have to demonstrably the comply with the legal requirements of Medical Device Directiv.

Our network isolators, USB isolators, RS232 isolators or video isolators, they solve a problem that occurs in almost all medical facilities, hospitals and clinics: high leakage currents over the (data) line and possibly also over the patient. This is a growing risk factor, especially in connection with the increasing digitalization of healthcare. As soon as an electrical device within the patient environment is connected to the server via an electrical (data) line, the standards for electrical safety in medical technology, IEC 60601-1, require the electrical isolation of the signal line. Baaske Medical's isolators solve this problem by isolating currents and voltages on the (data). Due to the fact they cannot reach the patient. Even if the data processing device is located outside the patient environment.

Network isolators | RS232- | USB- | Video- Isolators

 

Network_Isolators5c17688cdea0d
RS232_Isolators5c176890206b8
Isolators_USB5c1768894a93f
Video_Isolators5c17689293039

For the isolation of medical electrical devices, Baaske Medical offers a comprehensive product portfolio for network isolators, RS232 isolators, USB isolators and video isolators.

For further questions please do not hesitate to contact me.

We are glad to advise you by the safe combination of medical devices with modern IT.

 

Isolators for medical applications Galvanic isolation of medical electrical devices. Network isolators and isolators for the patient environment are used in the medical field to... read more »
Close window
Network isolators and galvanic isolation of medical electrical equipment

Banner_Netzwerkisolator_network_isolator_

Isolators for medical applications

Galvanic isolation of medical electrical devices.

Network isolators and isolators for the patient environment are used in the medical field to protect the patient from vagabonding currents, also-called leakage and compensating currents. This currents can occur when an active medical device is connected to a non-medical device such as an office PC or laptop. When healthcare facilities combine medical electrical devices, they have to demonstrably the comply with the legal requirements of Medical Device Directiv.

Our network isolators, USB isolators, RS232 isolators or video isolators, they solve a problem that occurs in almost all medical facilities, hospitals and clinics: high leakage currents over the (data) line and possibly also over the patient. This is a growing risk factor, especially in connection with the increasing digitalization of healthcare. As soon as an electrical device within the patient environment is connected to the server via an electrical (data) line, the standards for electrical safety in medical technology, IEC 60601-1, require the electrical isolation of the signal line. Baaske Medical's isolators solve this problem by isolating currents and voltages on the (data). Due to the fact they cannot reach the patient. Even if the data processing device is located outside the patient environment.

Network isolators | RS232- | USB- | Video- Isolators

 

Network_Isolators5c17688cdea0d
RS232_Isolators5c176890206b8
Isolators_USB5c1768894a93f
Video_Isolators5c17689293039

For the isolation of medical electrical devices, Baaske Medical offers a comprehensive product portfolio for network isolators, RS232 isolators, USB isolators and video isolators.

For further questions please do not hesitate to contact me.

We are glad to advise you by the safe combination of medical devices with modern IT.

 

Close filters
3 From 3
Related products
Hint!
networ isolator MI1005 MB
Network Isolator MI 1005 MB Order number: 2007704
Network Isolator MI 1005 MB | Wall-mounted medical network isolator | 10/100/1000 MBit/s | 5 kV AC / 10 kV DC (10 sec) | 2 x RJ45
Z Isolator 1000G Blende
Z isolator 1000G faceplate Order number: 2006189
Z isolator 1000G faceplate. | Covers the visible edges of the isolator housing.
Netzwerk Geräteeinbau Isolator 1000G
1000G built-in network device isolator Order number: 2006155
1000G built-in network device isolator without front panel bit rate: 10/100/1000 Mb/s test voltage 4 kV AC UL recognized component
HARTING PushPull Anbaugehäuse Compact
HARTING PushPull mounting housing Compact Order number: 2006634
HARTING PushPull mounting housing Compact with integrated seal / Board drillings for M2.5 / with fixing clip / Plastic, black / for female insert angled
HARTING PushPull Anbaugehäuse Flach
HARTING PushPull mounting housing Flat Order number: 2007020
HARTING PushPull mounting housing Flat with integrated seal / Board drillings for M2.5 / with fixing clip / Plastic, black / for female insert angled Custom code 85366990
EmoSafe EN-30 Netzwerkisolator
EmoSafe EN-30 Ethernet Isolator Order number: 2010876
EmoSafe EN-30 Ethernet Isolator | Hardwearing aluminium housing with optionally usable mounting bracket | Transmission speeds: 10/100/1000 Mb/s | Dielectric strength: 4 kV AC / 5,6 kV DC | Standards: IEC 60601-1 (3rd.Ed), IEC 60601-1-2,...
EmoSafe EN-20G Netzwerkisolator
EmoSafe EN-20G Ethernet Isolator Order number: 2010875
EmoSafe EN-20G Ethernet Isolator for wall mounting| | Dielectric strength: 5,6 kV DC | Standards: IEC 60601-1 (3rd. Ed), IEC 60601-1-2, UL listed (E249126), CE, ROHS and REACH compliant
3 From 3